PRODUCT SELECTOR
&
CAD LIBRARY
Stay Connected with PennEngineering®
|
1) Engage all threads of the fastener on the pull-up stud. Advance anvil until it is tight on head of fastener (Fig. 1). Insert fastener into installation hole.
2) Place hex wrench in socket of jackscrew and hold stationary. Turn hex nut in clockwise direction with a wrench while holding tool at right angle to the work.

Figure 1. Figure 2.
3) Turn nut until firm resistance indicates a complete upset of the fastener (Fig 2).
4) Break nut loose with counter clockwise movement. Remove both wrenches from the tool.
5) Remove tool from fastener by revolving entire tool in counter clockwise direction.
Thread Size |
Complete Tool Part Number |
4-40 |
L-845-440 |
6-32 |
L-845-632 |
8-32 |
L-845-832 |
10-24 |
L-845-1024 |
10-32 |
L-845-1032 |
1/4-20 |
L-845-2520 |
1/4-28 |
L-845-2528 |
5/16-18 |
L-722-3118 |
5/16-24 |
L-722-3124 |
3/8-16 |
L-722-3716 |
3/8-24 |
L-722-3724 |
1/2-13 |
L-722-5013 |
1/2-20 |
L-722-5020 |
M3 |
L-845-M3 |
M4 |
L-845-M4 |
M5 |
L-845-M5 |
M6 |
L-845-M6 |
M8 |
L-722-M8 |
M10 |
L-722-M10 |
M12 |
L-722-M12 |
|
|